Coaxial cable SAT703N, 75 Ohm

 

Specifications:
Fire protection - CM
Braid coverage according to IEC 96-1
Screening Class B

Description:
The coaxial cable with low attenuation level and improved performance. Dielectric of physical foam polyethylene in the cable structure allows for better stability and electrical characteristics as compared to a chemically foamed insulation. Screening attenuation not less than 75 dB. Screening Class B. The cable is designed for application in the networks of cable television as a drop cable and is intended for indoor installation.

Materials:
Conductor: wire of annealed electrolytic copper, solid
Insulation: foam polyethylene
Shield: polyether foil with aluminum alloy on both sides and tinned copper wire braid 
The cable jacket: lead-free PVC

Technical characteristics:
Conductor diameter: 1.13 mm (0.045") (17 AWG)
Insulation Diameter: 4.8 mm (0.19") 
Outer cable diameter: 6.6 mm (0.26") 
Jacket color: black or white
Shield (coverage): polyether foil - 100% covering density; braid - 45% coverage
Screening factor (attenuation): ≥ 75 dB
Max. pulling tension: 150 N
Min. bending radius (installation): 35.0 mm (1.38")
Min. bending radius (operation): 70.0 mm (2.76")
Storage temperature: -20°C - +70°C (-68°F - +158°F)
Operating temperature: -40°C - +70°C (-104°F - +158°F)
Weight of copper conductors per 1000 ft (304.8 m): 4.4 kg (9.7 lbs)
Weight per 1000 ft (304.8 m): 12.0 kg (26.5 lbs)

Electrical characteristics:
Frequency, MHz Attenuation (dB/100M) at 20°C (-68°F)
5 1.60
10 2.10
30 3.20
50 4.10
200 7.90
300 9.80
470 12.40
862 17.10
1000 18.50
1750 24.90
2150 27.90
2400 29.60
3000 33.40

Characteristic impedance (at 200 MHz) 75 ± 3 Ohm
Capacitance 52 ± 2 pF/m
DCR: Inner conductor 18 Ohm/km 18 Ohm/km
DCR: Outer conductor 22 Ohm/km
Insulation voltage of the jacket (spark test) 3000 V
Maximum current (Ieff) 8.0 A
Return Loss at
5 - 470 MHz
470 - 1000 MHz
1000 - 2000 MHz
2000 - 3000 MHz

≥ 30 dB
≥ 28 dB
≥ 26 dB
≥ 22 dB
Screening factor (attenuation) at 
30 - 1000 MHz
1000 - 2000 MHz
2000 - 3000 MHz

≥ 80 dB
≥ 80 dB
≥ 70 dB
Transfer impedance at 5 - 30 MHz 1.5 mOhm/m