Shielded Twisted Pair Cable SFTP, category 5e, 4 pairs, solid

Shielded Twisted Pair Cable SFTP, category 5e, 4 pairs, solid
Shielded Twisted Pair Cable SFTP, category 5e, 4 pairs, solid 1 – Jacket
2 – Shield-braid
3 – Drain wire
4 – Protective skin
5 – Solid twisted pair
Shielded Twisted Pair Cable SFTP, category 5e, 4 pairs, solid
Specifications:
Meets ANSI/EIA/TIA 568-B.2 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard


Description:
Shielded Copper cable, 4 pairs, category 5e, solid
Shield: aluminum foil and wire braid
The cable meets UL 444 UL 1581 fire safety standard

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
An aluminum tape shield is helically applied over the cable core with a minimum overlap of 25% or 5 mm (0.19"), thickness – 0.025 mm (0.001"), width – 20 mm (0.78"), and braid of 16 tinned Copper wires

Technical characteristics:
Application: horizontal wiring in LAN Conductor diameter: 0.02" (0.51 mm) (24 AWG)
Insulated conductor diameter: 0.035" ± 0.001" (0.9 ± 0.02 mm)
Outer cable diameter: 0.24" ± 0.012" (6.1 ± 0.3 mm)
Shield: aluminum foil and tinned copper wire braid
Jacket thickness: 0.015" (0.4 mm)
Minimum bend radius: 4 outer cable diameters
Conductor elongation: 14% minimum
Drain wire diameter: 0.019" (0.5 mm)
Operating temperature: –4°F to +167°F (–20°C to +75°C)
Weight per 1000 ft: 32.9 lbs (14.9 kg)
Standard package: 1000 ft (305 m)

Electrical characteristics
Frequency, MHz RL Attenuation, dB NEXT, dB PSNEXT, dB ELFEXT, dB PSELFEXT, dB
0.772 - 1.8 67.0 64.0 - -
1.0 20.0 2.0 65.3 62.3 63.8 60.8
4.0 23.0 4.0 56.3 53.3 51.7 48.7
8.0 24.5 5.8 51.8 48.8 45.7 42.7
10.0 25.0 6.5 50.3 47.3 43.8 40.8
16.0 25.0 8.2 47.3 44.3 39.7 36.7
20.0 25.0 9.3 45.8 42.8 37.7 34.7
25.0 24.3 10.4 44.3 41.3 35.8 32.8
31.25 23.6 11.7 42.9 39.9 33.9 30.9
62.5 21.5 17.0 38.4 35.4 27.8 24.8
100.0 20.1 22.0 35.3 32.3 23.8 20.8


Max conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
Max Resistance Unbalance 5%
Max pair-to-ground capacitance unbalance 330 pF/100 m (101 pF/100 ft)
Characteristic Impedance at 0.772-100 MHz 85-115 Ohm
Mutual capacitance 5.6 nF/m (1.7 nF/ft)
Spark Test 2.5 kV

Ordering
SFTP4-C5E-SOLID-GY Shielded Twisted Pair Cable SFTP, category 5e, 4 pairs, solid, gray

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber