American Tech Supply is now an authorized Hyperline distributor
From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.
Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7 requirements and ISO/IEC
11801 category 7 requirements
Fire protection – CM
The cable meets UL 1581 VW-1, IEC 60332-1 fire safety standard
Description:
Shielded Copper cable, 4 pairs, category 7 (1000 MHz, 10GbE), stranded (patch)
4 separately foil-shielded pairs
General shield: wire braid
Cable is used for indoor installation
Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: PO
The cable jacket: FR-LSZH (fire resistant low smoke zero halogen)
Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair
General shield: tin Copper braid – 65% minimum
Technical characteristics:
Conductor diameter: 7 x 0.17 mm (7 x 0.007") (26 AWG)
Outer cable diameter: 6.5 (0.27")
Operating temperature: -20°C - +70°C (-4°F - +158°F)
Weight per 1000 ft (304.8 m): 13.7 kg (30.2 lbs)
Standard package: 500 m (1640 ft)
Electrical characteristics:
Freq., MHz
Attenuation, dB/100m 20°C
PSNEXT, dB
NEXT, dB
RL, dB
PS ANEXT, dB
PS ELFEXT, dB
ELFEXT, dB
Typical Value
Cat. 7
Typical Value
Cat. 7
Typical Value
Cat. 7
Typical Value
Cat. 7
Typical Value
Cat. 7
Typical Value
Cat. 7
Typical Value
Cat. 7
1
2.9
3.0
105.0
99.4
108.0
102.4
22.0
20.0
68.0
-
95.0
75.0
98.0
78.0
4
5.4
5.6
98.0
90.4
101.0
93.4
25.0
23.0
68.0
-
90.0
75.0
93.0
78.0
10
8.5
8.8
95.0
84.4
98.0
87.4
28.0
25.0
68.0
-
86.0
71.0
89.0
74.0
20
12.1
12.4
90.0
80.0
93.0
83.0
28.0
25.0
68.0
-
80.0
65.0
83.0
68.0
30
14.8
15.3
85.0
77.2
88.0
80.2
27.0
23.8
68.0
-
76.0
61.5
79.0
64.5
100
27.7
28.5
80.0
69.4
83.0
72.4
24.0
21.1
68.0
-
66.0
51.0
69.0
54.0
150
34.3
35.3
78.0
66.7
81.0
69.7
22.0
18.8
65.0
-
63.0
47.5
66.0
50.5
200
40.0
41.2
78.0
65.0
81.0
68.0
21.0
18.0
65.0
-
60.0
45.0
63.0
48.0
250
45.1
46.5
75.0
63.4
78.0
66.4
20.0
17.3
62.0
-
58.0
43.0
61.0
46.0
300
49.7
51.3
75.0
62.2
78.0
65.2
19.0
17.3
62.0
-
52.0
41.5
55.0
44.5
400
58.2
60.0
70.0
60.4
73.0
63.4
19.0
17.3
62.0
-
49.0
38.9
52.0
41.9
500
65.8
67.9
70.0
58.9
73.0
61.9
19.0
17.3
62.0
-
47.0
37.0
50.0
40.0
600
72.9
75.1
70.0
57.7
73.0
60.7
19.0
17.3
62.0
-
45.0
35.4
48.0
38.4
Conductor resistance at 20°C (68°F)
80.0 Ohm/km (128.75 Ohm/mile)
DC Resistance Unbalance
2% max
Resistance at frequency 1-600 MHz
100 ± 15 Ohm
Transfer impedance at frequency 1-10 MHz
5 MOhm/m (1.52 MOhm/ft) max
Capacitive unbalance at frequency 1 kHz
1.2 pF/m (0.36 pF/ft) max
Maximum voltage
60 V RMS
Dielectric rigidity
700 V/min
Insulation resistance at 20°C (68°F)
152 MOhm/km (244.62 MOhm/mile) minimum
Propagation velocity
79-80%
Max propagation delay at frequency 1 MHz
5.3 ns/m (1.61 ns/ft)
Max propagation delay at frequency 10 MHz
5.0 ns/m (1.52 ns/ft)
Max propagation delay at frequency 100-600 MHz
5.0 ns/m (1.52 ns/ft)
Max derivation of propagation delay at frequency 1-600 MHz