Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Shielded twisted pair cable SSTP, category 7 (1200 MHz), 4 pairs, solid, 22 AWG, LSZH

Shielded twisted pair cable SSTP, category 7 (1200 MHz), 4 pairs, solid, 22 AWG, LSZH
1 – Jacket 
2 – Shield-braid
3 – Drain wire 
4 – Shield-foil
5 – Solid twisted pair

Specifications:
Meets ISO/IEC 11801 (2nd edition) and exceeds ISO/IEC 11801 for D, E, F classes and IEC 61156-5, IEC 61156-7 category 5e, 6, 7 requirements
Fire protection – CM
The cable meets UL 1581 VW-1, IEC 60332-1 fire safety standard

Description:
Shielded Copper cable, 4 pairs, category 7, solid
4 separately foil-shielded pairs
General shield: wire braid
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE, film-porous-film structure
The cable jacket: LSZH (low smoke zero halogen)
Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair
General shield: tin Copper braid–70% minimum

Technical characteristics:
Conductor diameter: 0.64 mm (0.025") (22 AWG)
Outer cable diameter: 8.7 mm (0.34")
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft (304.8 m): 24.4 kg (53.8 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequ-
ency, MHz
Inserted
losses, dB/100m (dB/100ft)
NEXT, dB PS NEXT, dB RL, dB Phase shift,
ns/100 m (ns/100 ft)
Delay,
ns/100m (ns/100ft)
Attenu-
ation, dB
Data transi-
stance,
MOhm/m (MOhm/ft)
Attenu-
ation
of shield, dB
1 1.9 (0.6) 90 87 23 20 (6.10) 518 (157.9) - 15 (4.6) -
4 3.4 (1.0) 90 87 23 20 (6.10) 509 (155.2) - - -
10 5.4 (1.6) 90 87 23 20 (6.10) 505.7 (154.17) - 10 (3.0) -
16 6.8 (2.0) 90 87 23 20 (6.10) 504.5 (153.81) - - -
30 9.3 (2.8) 90 87 23 20 (6.10) 503.3 (153.45) 90 30 (9.1) 65
54.1 12.7 (3.9) 90 87 23 20 (6.10) 502.4 (153.17) 90 - 65
62.5 13.7 (4.2) 89.1 86.1 23 20 (6.10) 502.3 (153.14) 90 - 65
100 17.5 (5.3) 86 83 23 20 (6.10) 501.8 (152.98) 90 - 65
200 25.3 (7.7) 81.5 78.5 23 20 (6.10) 501.3 (152.83) 84 - 65
300 31.5 (9.6) 78.8 75.8 23 20 (6.10) 501 (152.74) 80.5 - 65
600 46.3 (14.1) 74.3 71.3 20 20 (6.10) 500.7 (152.65) 74.4 - 65
900 58.4 (17.8) 71.7 68.7 18.2 20 (6.10) 500.6 (152.62) 70.9 - 65
1000 62 (18.9) 71 68 17.8 20 (6.10) 500.6 (152.62) 70 - 65
1200 69 (21.0) 69.8 66.8 17 20 (6.10) 500.5 (152.59) 68.4 - 65


Conductor resistance at 20°C (68°F) 59.0 Ohm/km (95.2 Ohm/mile)
DC Resistance Unbalance 2% max
Transfer impedance at 30 MHz 30 MOhm/m max (9.14 MOhm/ft)
Resistance at 1-1200 MHz 100 ± 5 Ohm
Insulation resistance 20°C (68°F) 152 MOhm/km (244.62 MOhm/mile) minimum
Capacitive unbalance at 1 kHz relative to earth 1.5 pF/m (0.46 pF/ft)
Capacity at kHz 43 pF/m (13.1 pF/ft)
Maximal voltage 60 B RMS
Propagation velocity 79-80%
Dielectric power 700 V/1min

Ordering:
SSTP4-C7-SOLID-INDOOR Shielded twisted pair cable SSTP, category 7 (1200 MHz), 4 pairs, solid, 22 AWG, LSZH

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber