American Tech Supply is now an authorized Hyperline distributor
From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.
Meets IEC 61156 requirements and ISO 11801, RoHS 2002/95/EC
The cable meets IEC 60332-1 fire safety standard
Description:
Shielded Copper cable, 4 pairs, category 7, solid
4 separately foil-shielded pairs
General shield: wire braid
Trunk cable is used for Local Area Networks, indoor/outdoor use, low temperature conditions. The cable is used for high bandwidth digital applications with low BER, high data rates, data processing and information systems.
Materials:
Conductive material: bare copper
Conductor insulation: cellular PO
The cable jacket: UV-resistant polyethylene (PE), black
Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair
General shield: tinned copper braid - 65% minimum
Drain wire: tinned copper
Technical characteristics:
Conductor diameter: 0.64 mm (0.03") (23 AWG)
Insulated conductor diameter: 1.56 mm (0.06")
Outer cable diameter: 9.9 mm (0.39")
Drain wire diameter: 23 AWG
Minimum bend radius: 120 mm (4,72")
Pulling strength: 14 N max.
Operating temperature: -55°C - +70°C (-67°F - +158°F)
Weight per 1000 ft (304.8 m): 61,82 lbs (28.04 kg)
Copper weight in 1000 ft (304.8 m) of cable: 29,56 lbs (13.41 kg)
Standard package: 500 m (1640 ft)