Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Shielded twisted pair cable (SSTP), Category 8 (1200 MHz), 4 pairs, Solid, Outdoor, 22 AWG, PE

1 - Jacket
2 - Shield-braid 
3 - Drain wire
4 - Shield-foil
5 - Solid twisted pair
Specifications:
Meets IEC 61156 requirements and ISO 11801, RoHS 2002/95/EC
The cable meets IEC 60332-1 fire safety standard

Description:
Shielded Copper cable, 4 pairs, category 7, solid
4 separately foil-shielded pairs
General shield: wire braid
Trunk cable is used for Local Area Networks, indoor/outdoor use, low temperature conditions. The cable is used for high bandwidth digital applications with low BER, high data rates, data processing and information systems.

Materials:
Conductive material: bare copper
Conductor insulation: cellular PO
The cable jacket: UV-resistant polyethylene (PE), black
Shield: every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair
General shield: tinned copper braid - 65% minimum
Drain wire: tinned copper

Technical characteristics:
Conductor diameter: 0.64 mm (0.03") (23 AWG)
Insulated conductor diameter: 1.56 mm (0.06")
Outer cable diameter: 9.9 mm (0.39")
Drain wire diameter: 23 AWG
Minimum bend radius: 120 mm (4,72")
Pulling strength: 14 N max.
Operating temperature: -55°C - +70°C (-67°F - +158°F)
Weight per 1000 ft (304.8 m): 61,82 lbs (28.04 kg)
Copper weight in 1000 ft (304.8 m) of cable: 29,56 lbs (13.41 kg)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequency, MHz Attenuation at 20°C, dB/100m PS NEXT, dB NEXT, dB RL, dB PS ANEXT, dB PS ELFEXT, dB ELFEXT, dB
Typical Value Cat. 7A Typical Value Typical Value Cat. 7A Typical Value Cat. 7A Typical Value Cat. 7A Typical Value Cat. 7A Typical Value Cat. 7A
1 1.9 2.0 107.0 110.0 108.4 22.0 20.0 70.0 67.0 95.0 75.0 98.0 78.0
4 3.4 3.8 98.0 101.0 99.3 25.0 23.0 70.0 67.0 90.0 75.0 93.0 78.0
10 5.4 5.8 95.0 98.0 93.4 28.0 25.0 70.0 67.0 86.0 71.0 89.0 74.0
20 8.0 8.2 90.0 93.0 88.9 28.0 25.0 70.0 67.0 80.0 65.0 83.0 68.0
30 9.3 10.1 90.0 93.0 86.2 27.0 23.8 70.0 67.0 76.0 61.5 79.0 64.5
100 17.5 18.5 80.0 83.0 78.4 24.0 21.1 70.0 62.5 66.0 51.0 69.0 54.0
200 25.4 26.5 80.0 83.0 75.7 22.0 18.8 68.0 59.8 63.0 47.5 66.0 50.5
200 25.6 26.5 80.0 83.0 73.8 21.0 18.0 68.0 58.0 60.0 45.0 63.0 48.0
300 31.5 32.7 77.0 80.0 72.4 20.0 17.3 65.0 56.5 58.0 43.0 61.0 46.0
600 46.3 47.1 77.0 80.0 71.2 19.0 17.3 65.0 55.3 52.0 41.5 55.0 44.5
900 58.4 61 72.0 75.0 69.3 19.0 17.3 65.0 53.4 49.0 38.9 52.0 41.9
1000 60 62 72.0 75.0 67.9 19.0 17.3 65.0 52.0 47.0 37.0 50.0 40.0
1100 64 - 72.0 75.0 - 19.0 - 65.0 - 45.0 - 48.0 38.4
1500 71 - 72.0 75.0 - 19.0 - 65.0 - 39.0 - 42.0 34.0

Conductor DC resistance at 20°C (68°F) 57 Ohm/km (91.77 Ohm/mile)
Impedance 100 Ohm
DC Resistance Unbalance 2% max.
Insulation resistance 5 GOhm/km (8 GOhm/mile)
Capacitive unbalance 1,2 pF/m (0.36 pF/ft) max.
Propagation delay skew 25 ns/100 m (7.62 ns/100 ft) max.
Dielectric strength 700 V/min
Dielectric strength to shield 700 V/min

Ordering
SSTP4-C8-SOLID-OUTDOOR-55 Shilded twisted pair cable (SSTP), 4 pairs, category 8 (1200 MHz), solid, indoor, 22 AWG, UV-resistant PE

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber