From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Twisted Pair Cable (USTP), 4 pairs, Category 6a (500 MHz), Solid, Indoor/Outdoor, 23 AWG, FR-LSZH PU

1 - Outer UV-resistant jacket
2 - Inner jacket
3 - Shield-foil
4 - Drain wire
5 - Solid twisted pair
Specifications:
Meets ISO/IEC 11801, TIA/EIA-568 requirements
The cable meets IEC 60332-1, UL 1581 VW-1 fire safety standards

Description:
Copper cable, 4 pairs, category 6a, solid. 4 separately foil shielded twisted pairs are jacketed with FR-LSZH compound and an additional black UV-resistant FR-LSZH PU (fire resistant low smoke zero halogen polyurethane) jacket.
Cable is used for indoor/outdoor installation, high bandwidth digital applications with low BER, high data rates.

Materials:
Conductive material: bare copper
Conductor insulation: PO, film-porous-film structure
The outer cable jacket: FR-LSZH PU, UV-resistant
The inner cable jacket: FR-LSZH
every pair is separately shielded with polyester aluminum foil (foil is on the outside), which covers 100% of twisted pair 
Drain wire: tinned copper

Technical characteristics:
Conductor diameter: 23 AWG
Insulated conductor diameter: 1.34 mm (0.05")
Outer cable diameter: 9.0 mm (0.35")
Inner jacket thickness: 0.5 mm (0.02")
Inner jacketed cable diameter: 7.4 (0.29")
Drain wire diameter: 0.41 mm (0.02")
Pulling strength: 160 N max.
Minimum bend radius: 120 mm (4.72")
Operating temperature: -40°C - +70°C (-40°F - +158°F)
Weight per 1000 ft (304.8 m): 50.4 lbs (22.86 kg)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Frequency, MHz Attenuation at 20°C, dB/100m PS NEXT, dB NEXT, dB RL, dB PS ANEXT, dB PS ELFEXT, dB ELFEXT, dB
Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A
1 3.0 3.1 95.0 72.3 98.0 75.3 22.0 20.0 70.0 67.0 85.0 65.0 88.0 68.0
4 5.6 5.8 95.0 63.3 98.0 66.3 25.0 23.0 70.0 67.0 73.0 53.0 76.0 56.0
10 8.7 9.0 95.0 57.3 98.0 60.3 28.0 25.0 70.0 67.0 65.0 45.0 68.0 48.0
20 12.4 12.8 90.0 52.8 93.0 55.8 28.0 25.0 70.0 67.0 59.0 39.0 62.0 42.0
30 15.3 15.8 85.0 50.1 88.0 53.1 27.0 23.8 70.0 67.0 55.4 35.4 58.4 38.4
100 29.0 29.9 80.0 42.3 83.0 45.3 24.0 21.1 67.0 62.5 45.0 25.0 48.0 28.0
150 36.2 37.4 78.0 39.7 81.0 42.7 22.0 18.8 66.0 59.8 41.5 21.5 44.5 24.5
200 42.5 43.8 78.0 37.8 81.0 40.8 21.0 18.0 65.0 58.0 49.0 19.0 52.0 22.0
250 48.2 49.7 75.0 36.3 78.0 39.3 20.0 17.3 63.0 56.5 37.0 17.0 40.0 20.0
300 53.4 55.1 75.0 35.1 78.0 38.1 19.0 17.3 62.0 55.3 35.5 15.5 38.5 18.5
400 63.1 65.1 70.0 33.3 73.0 36.3 19.0 17.3 61.0 53.4 33.0 13.0 36.0 16.0
500 71.9 74.0 70.0 31.8 73.0 34.8 19.0 17.3 59.0 52.0 31.0 11.0 34.0 14.0

Frequency Range 1 - 500 MHz
Impedance 100 Ω
Coupling Attenuation Type I
DC Resistance 73 Ω/km nom.
Max. Resistance Unbalance 2 %
Capacitance Unbalance 1.2 pF/m max.
Propagation Delay Skew 35 ns/100m max.
Dielectric Strength 700 V/minute
Dielectric Strength to Shield 700 V/minute
Max. Tensile Strength - Short Term 160 N
Min. Bend Radius 120 mm
Max. Operating Temperature +70 °C
Min. Operating Temperature -40 °C

Ordering
USTP4-C6a-SOLID-OUTDOOR Twisted pair cable (USTP), 4 pairs, category 6a, solid, indoor/outdoor, for unshielded application, FR-LSZH PU

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber