Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Shielded Twisted Pair Cable (USTP), 4 pairs, Solid, Indoor, Category 6A

Shielded twisted pair cable (USTP), category 6a, 4 pairs, solid, 23AWG, PVC
1 – Jacket
2 – Shield-foil
3 – Solid twisted pair

Specifications:
Meets IEC 61156-5, ISO/IEC 11801 and EIA/TIA 568-B.2-1 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard

Description:
Shielded Copper cable, 4 pairs, Category 6A, solid
4 separately foil-shielded pairs
Cable is used for indoor installation and unshielded systems

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: PE, film-porous-film structure
The cable jacket: FR-PVC
Shield: every pair is separately shielded with polyester aluminum foil, which covers 100% of twisted pair

Technical characteristics:
Conductor diameter: 0.57 ± 0.01mm (0.022" ± 0.004") (23 AWG)
Insulated conductor diameter: 1.43 mm (0.056")
Outer cable diameter: 8 mm (0.31")
Jacket thickness: 0.5 mm (0.019")
Pulling strength: 130 N maximum
Minimum bend radius: 50 mm (1.97")
Repeated bending: 80 cycles
Rip cord has a breaking strength of 10 kg (98 N)
Operating temperature: -30°C – +70°C (+22°F – +158°F)
Weight per 1000 ft (304.8 m): 16.8 kg (37 lbs)
Standard package: 500 m (1640 ft)

Electrical characteristics:
Cat. 6A Screened-pair Work Area Cables*
Frequency, MHz Attenuation, dB/100 m 20°C PS NEXT Loss, dB NEXT Loss, dB RL, dB PS ANEXT, dB PS ELFEXT, dB ELFEXT, dB
Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A Typical Value Cat. 6A
1 3.0 3.1 95.0 72.3 98.0 75.3 22.0 20.0 70.0 67.0 85.0 65.0 88.0 68.0
4 5.6 5.8 95.0 63.3 98.0 66.3 25.0 23.0 70.0 67.0 73.0 53.0 76.0 56.0
10 8.7 9.0 95.0 57.3 98.0 60.3 28.0 25.0 70.0 67.0 65.0 45.0 68.0 48.0
20 12.4 12.8 90.0 52.8 93.0 55.8 28.0 25.0 70.0 67.0 59.0 39.0 62.0 42.0
30 15.3 15.8 85.0 50.1 88.0 53.1 27.0 23.8 70.0 67.0 55.4 35.4 58.4 38.4
100 29.0 29.9 80.0 42.3 83.0 45.3 24.0 21.1 67.0 62.5 45.0 25.0 48.0 28.0
150 36.2 37.4 78.0 39.7 81.0 42.7 22.0 18.8 66.0 59.8 41.5 21.5 44.5 24.5
200 42.5 43.8 78.0 37.8 81.0 40.8 21.0 18.0 65.0 58.0 49.0 19.0 52.0 22.0
250 48.2 49.7 75.0 36.3 78.0 39.3 20.0 17.3 63.0 56.5 37.0 17.0 40.0 20.0
300 53.4 55.1 75.0 35.1 78.0 38.1 19.0 17.3 62.0 55.3 35.5 15.5 38.5 18.5
400 63.1 65.1 70.0 33.3 73.0 36.3 19.0 17.3 61.0 53.4 33.0 13.0 36.0 16.0
500 71.9 74.0 70.0 31.8 73.0 34.8 19.0 17.3 59.0 52.0 31.0 11.0 34.0 14.0
* Supplied cables meet the minimum Cat. 6A transmission requirements as per IEC 61156-6 Ed. 2

Frequency range 1-500 MHz
Impedance 100 Ohm
Max conductor resistance at 20°C (68°F) 9.38 Ohm/100 m (2.9 Ohm/100 ft)
Max Resistance Unbalance 2%
Capacitance unbalance 1.2 pF/m max
Max pair-to-ground capacitance unbalance 330 pF/100 m (101 pF/100 ft)
Characteristic Impedance at 0.772-100 MHz 85-115 Ohm
Mutual capacitance 5.6 nF/m (1.7 nF/ft)
Min. insulation resistance 5 GOhm/km
Spark Test 2.5 kV

Ordering:
USTP4-C6A-SOLID-INDOOR Shielded twisted pair cable (USTP), 4 pairs, solid, indoor, category 6A

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber