Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Unshielded Twisted Pair Cable (UTP), 25/50/100 pairs, Solid, Indoor, Category 5

Unshielded twisted pair cable UTP, category 5, 10 pairs, solid
Unshielded Twisted Pair Cable (UTP), 10 pairs 

Unshielded twisted pair cable UTP, category 25 pairs, solid
Unshielded Twisted Pair Cable (UTP), 25 pairs 

Unshielded Twisted Pair Cable (UTP), 25/50/100 pairs, Solid, Indoor, Category 5 1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Solid twisted pair
5 – Main load-bearing element
Specifications:
Meets EIA/TIA 568-A requirements
Fire protection – CMX
The cable meets UL 1581 VW-1 fire safety standard

Description:
Unshielded Copper cable, 25/50/100 pairs, category 5, solid
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC

Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.92 mm (0.035")
Outer cable diameter: 12.5 – 23 mm (0.49" – 0.9")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 6 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Pulling strength: 500 N Breaking strength: 600 N Installation temperature: -5°C – +40°C (+23°F – +104°F)
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 48.8 – 167.6 kg (107.5 – 369.6 lbs)
Standard package: 500 – 1000 m (1640 – 3280 ft)


Electrical characteristics:
Frequency, MHz Max attenuation, dB/100 m (dB/100 ft) Min PS-NEXT losses, dB Low value PS-ACR, dB/100 m (dB/100 ft)
0.772 1.8 (0.55) 64 62.2 (19.0)
1.0 2.0 (0.6) 62 60.0 (18.3)
4.0 4.1 (1.3) 53 48.9 (14.9)
8.0 5.80 (1.8) 48 42.2 (12.9)
10.0 6.5 (2.0) 47 40.5 (12.3)
16.0 8.2 (2.5) 44 35.8 (10.9)
20.0 9.3 (2.8) 42 32.8 (10.0)
25.0 10.4 (3.2) 41 30.6 (9.3)
31.25 11.7 (3.6) 39 28.3 (8.6)
62.5 17.0 (5.2) 35 18.0 (5.5)
100.0 22.0 (6.7) 32 10.0 (3.0)


Max. direct-current resistance at 20°C (68°F) 93.8 Ohm/km (151.3 Ohm/mile)
Resistance at the frequency of 1-100 MHz 100 ± 15 Ohm
Resistance unbalance 3%
Capacity at the frequency of 1 kHz 50 ± 4 pF/m (15.3 ± 1 pF/ft)
Capacitive unbalance at the frequency of 1 kHz 3300 pF/km (5322.6 pF/mile)
Maximum voltage 300 V
Min. unbalance losses at the frequency of 64 kHz 43 dB
Insulating strength 700 V RMS
Propagation velocity 68%
Max. propagation delay
at the frequency of 1 MHz
at the frequency of 10 MHz
at the frequency of 100 MHz

5.7 ns/m (1.74 ns/ft)
5.4 ns/m (1.64 ns/ft)
5.3 ns/m (1.61 ns/ft)
Derivation propagation delay 35 ns/100 m (10.67 ns/100 ft)
Min. insulating resistance 5 GOhm/km (8.05 GOhm/mile)

Ordering:
UTPXXM-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 25/50/100 pairs, solid, indoor, category 5