American Tech Supply is now an authorized Hyperline distributor
From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 for category 5 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard
Description:
Unshielded multi-pair copper cable, 12/16/24/48/100 pairs, category 5, solid. Cable consists of unshielded (UTP) bunches (Ø0.16" (4 mm)) of 4 twisted pairs each
Cable is used for indoor installation
Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC
Electrical characteristics:
Frequency, MHz
Max Attenuation, dB/100 m (dB/100 ft)
PS NEXT Loss, dB
Min PS-ACR, dB/100 m (dB/100 ft)
0.772
1.8 (0.55)
64
62.2 (19.0)
1.0
2.0 (0.6)
62
60.0 (18.3)
4.0
4.1 (1.3)
53
48.9 (14.9)
8.0
5.80 (1.8)
48
42.2 (12.9)
10.0
6.5 (2.0)
47
40.5 (12.3)
16.0
8.2 (2.5)
44
35.8 (10.9)
20.0
9.3 (2.8)
42
32.8 (10.0)
25.0
10.4 (3.2)
41
30.6 (9.3)
31.25
11.7 (3.6)
39
28.3 (8.6)
62.5
17.0 (5.2)
35
18.0 (5.5)
100.0
22.0 (6.7)
32
10.0 (3.0)
Max DC Resistance at 20°C
93.8 Ohm/km (151.3 Ohm/mile)
Max Resistance Unbalance
3%
Characteristic Impedance at 1-100 MHz
100 ± 15 Ohm
Capacitance at 1 kHz
50 ± 4 pF/m (15.3 ± 1 pF/ft)
Max Capacitance unbalance at 1 kHz
3300 pF/km (5322.6 pF/mile)
Longitudinal Conversion Loss at 64 kHz
43 dB
Max. Voltage rating
300 V
Dielectric Strength of Insulation
1000 V RMS
Max. Propagation Delay
at 1 MHz
at 10 MHz
at 100 MHz