Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Unshielded Twisted Pair Cable (UTP), 12/16/24/48/100 pairs, Category 5, Solid, Indoor


Twisted Pair Cable UTP, category 5, 8/10/12/16/24/48/100 pair, solid
Specifications:
Meets ANSI/EIA/TIA 568-A and ISO/IEC 11801 for category 5 requirements
Fire protection – CM
The cable meets UL 1581 VW-1 fire safety standard

Description:
Unshielded multi-pair copper cable, 12/16/24/48/100 pairs, category 5, solid. Cable consists of unshielded (UTP) bunches (Ø0.16" (4 mm)) of 4 twisted pairs each
Cable is used for indoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: PVC

Electrical characteristics:
Frequency, MHz Max Attenuation, dB/100 m (dB/100 ft) PS NEXT Loss, dB Min PS-ACR, dB/100 m (dB/100 ft)
0.772 1.8 (0.55) 64 62.2 (19.0)
1.0 2.0 (0.6) 62 60.0 (18.3)
4.0 4.1 (1.3) 53 48.9 (14.9)
8.0 5.80 (1.8) 48 42.2 (12.9)
10.0 6.5 (2.0) 47 40.5 (12.3)
16.0 8.2 (2.5) 44 35.8 (10.9)
20.0 9.3 (2.8) 42 32.8 (10.0)
25.0 10.4 (3.2) 41 30.6 (9.3)
31.25 11.7 (3.6) 39 28.3 (8.6)
62.5 17.0 (5.2) 35 18.0 (5.5)
100.0 22.0 (6.7) 32 10.0 (3.0)


Max DC Resistance at 20°C 93.8 Ohm/km (151.3 Ohm/mile)
Max Resistance Unbalance 3%
Characteristic Impedance at 1-100 MHz 100 ± 15 Ohm
Capacitance at 1 kHz 50 ± 4 pF/m (15.3 ± 1 pF/ft)
Max Capacitance unbalance at 1 kHz 3300 pF/km (5322.6 pF/mile)
Longitudinal Conversion Loss at 64 kHz 43 dB
Max. Voltage rating 300 V
Dielectric Strength of Insulation 1000 V RMS
Max. Propagation Delay
at 1 MHz
at 10 MHz
at 100 MHz

5.7 ns/m (1.74 ns/ft)
5.4 ns/m (1.64 ns/ft)
5.3 ns/m (1.61 ns/ft)
Propagation Delay Skew at 1-100 MHz 35 ns/100 m (10.67 ns/100 ft)
Insulation Resistance at 500 V 5 GOhm/km (8.05 GOhm/mile)
Nominal Velocity of Propagation 68%

12 pairs


Twisted Pair Cable (UTP) 12 pairs 1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 10 mm (0.39")
Jacket thickness: 0.8 mm (0.031")
Bend radius (installation): 20 outer cable diameters
Bend radius (operation): 10 outer cable diameters
Installation temperature: 0°C – +50°C (+32°F – +122°F)
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 28.3 kg (62.5 lbs)
Standard package: 1000 m (3280 ft)

16 pairs


Twisted Pair Cable (UTP) 16 pairs 1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 12 mm (0.47")
Jacket thickness: 0.8 mm (0.031")
Bend radius (installation): 20 outer cable diameters
Bend radius (operation): 10 outer cable diameters
Installation temperature: 0°C – +50°C (+32°F – +122°F)
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 36 kg (79.3 lbs)
Standard package: 1000 m (3280 ft)

24 pairs


Twisted Pair Cable UTP, category 5, 24 pair, solid 

Twisted Pair Cable (UTP) 24 pairs 1 – Jacket
2 – Rip-cord
3 – Polymer tape
4 – Protective skin
5 – Solid twisted pair
6 – Marking tape
7 – Central power member
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 13 mm (0.51")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Pulling strength: 500 N
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 51.8 kg (114.2 lbs)
Standard package: 1000 m (3280 ft)

48 pairs


Twisted Pair Cable UTP, category 5, 48 pair, solid 

Twisted Pair Cable (UTP) 48 pairs 1 – Jacket
2 – Rip-cord
3 – Polymer tape
4 – Protective skin
5 – Solid twisted pair
6 – Marking tape
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 17.6 mm (0.69")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Pulling strength: 500 N
Breakinh strength: 600 N
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 91.4 kg (201.6 lbs)
Standard package: 500 m (1640 ft)

100 pairs


Twisted Pair Cable UTP, category 5, 100 pair, solid 

Twisted Pair Cable (UTP) 100 pairs 1 – Jacket
2 – Rip-cord
3 – Polymer tape
4 – Protective skin
5 – Solid twisted pair
6 – Marking tape
7 – Central power member
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
Outer cable diameter: 25.6 mm (1")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Pulling strength: 500 N
Breaking strength: 600 N
Operating temperature: -20°C – +60°C (-4°F – +140°F)
Weight per 1000 ft: 180.4 kg (397.8 lbs)
Standard package: 500 m (1640 ft)
Ordering
UTPXX-C5-SOLID-INDOOR Unshielded twisted pair cable (UTP), 12/16/24/48/100 pairs, category 5, solid, indoor

XX – quantity of pairs: 12, 16, 24, 48, 100 pairs. 

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber