Ideal Product Categories

About Us

cable, vdsl, patch

 

Hyperline- Ideal Industries Cutters - Coax/Twisted Pair Cutters - Twisted Pair Cutters - Coax Cutters - Fiber Cutters Fiber Optic Test Equipment- Ideal Industries


American Tech Supply is now an authorized Hyperline distributor

From copper to fiber, the Hyperline system of products includes everything you need for installation, termination, testing and troubleshooting. And our level of technical expertise, training and customer support ensures that your total cost of ownership is kept to a minimum.

Unshielded Twisted Pair (UTP), 25/50/100 pairs, Solid, Outdoor, Category 5


Twisted Pair Cable UTP, category 5, 25/50/100 pairs, solid, outdoor
Specifications:
Meets EIA/TIA 568-A requirements
Fire protection – CMX
The cable meets UL 1581 VW-1 fire safety standard

Description:
Unshielded Copper cable, 25/50/100 pairs, category 5, solid
Cable is used for outdoor installation

Materials:
Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: HDPE
The cable jacket: UV resistant black PE

Electrical characteristics:
Frequency, MHz Max Attenuation, dB/100 m (dB/100 ft) PS NEXT Loss, dB Min PS-ACR, dB/100 m (dB/100 ft)
0.772 1.8 (0.55) 64 62.2 (19.0)
1.0 2.0 (0.6) 62 60.0 (18.3)
4.0 4.1 (1.3) 53 48.9 (14.9)
8.0 5.80 (1.8) 48 42.2 (12.9)
10.0 6.5 (2.0) 47 40.5 (12.3)
16.0 8.2 (2.5) 44 35.8 (10.9)
20.0 9.3 (2.8) 42 32.8 (10.0)
25.0 10.4 (3.2) 41 30.6 (9.3)
31.25 11.7 (3.6) 39 28.3 (8.6)
62.5 17.0 (5.2) 35 18.0 (5.5)
100.0 22.0 (6.7) 32 10.0 (3.0)


Max DC Resistance at 20°C 93.8 Ohm/km (151.3 Ohm/mile)
Max Resistance Unbalance 5%
Characteristic Impedance at 1-100 MHz 100 ± 15 Ohm
Capacitance at 1 kHz 50 ± 4 pF/m (15.3 ± 1 pF/ft)
Max Capacitance unbalance at 1 kHz 3300 pF/km (5322.6 pF/mile)
Longitudinal Conversion Loss at 64 kHz 43 dB
Max. Voltage rating 300 V
Dielectric Strength of Insulation 1000 V RMS
Max. Propagation Delay
at 1 MHz
at 10 MHz
at 100 MHz

5.7 ns/m (1.74 ns/ft)
5.4 ns/m (1.64 ns/ft)
5.3 ns/m (1.61 ns/ft)
Propagation Delay Skew at 1-100 MHz 35 ns/100 m (10.67 ns/100 ft)
Insulation Resistance at 500 V 5 GOhm/km (8.05 GOhm/mile)
Nominal Velocity of Propagation 68%

25 pairs

1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Solid twisted pair
5 – Main load-bearing element
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.92 mm (0.036")
Outer cable diameter: 12.4 mm (0.48")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 51.8 kg (114.2 lbs)
Standard package: 1000 m (3280 ft)

50 pairs

1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Solid twisted pair
5 – Main load-bearing element
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
The outer cable diameter (size): 12.6 x 22.8 mm (0.49" x 0.89")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 103.6 kg (228.5 lbs)
Standard package: 500 m (1640 ft)

100 pairs

1 – Jacket
2 – Rip-cord
3 – Protective skin
4 – Polymer tape
5 – Solid twisted pair
6 – Marking tape
7 – Load-bearing elements
Technical characteristics:
Conductor diameter: 0.51 mm (0.02") (24 AWG)
Insulated conductor diameter: 0.9 mm (0.035")
The outer cable diameter: 25.6 mm (1")
Jacket thickness: 0.8 mm (0.031")
Minimum bend radius: 10 outer cable diameters
Conductor elongation: 14% minimum
Rip cord has a breaking strength of 10 kg (98 N)
Installation temperature: -10°C to +40°C (+14°F to +104°F)
Operating temperature: -40°C to +70°C (-40°F to +158°F)
Weight per 1000 ft: 174 kg (383.7 lbs)
Standard package: 500 m (1640 ft)

Ordering:
UTPXX-C5-SOLID-OUTDOOR Unshielded twisted pair (UTP), 25/50/100 pairs, solid, outdoor, category 5

XX – quatity of pairs: 25, 50, 100 pairs

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

 

 

 

 

 

 

 

BIF-Bend Insensitive Fiber