SPECIFICATIONS
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX / 100BaseFX
IEEE 802.3x Flow Control and Back pressure
IEEE 802.3af Power over Ethernet, as Power Source Equipment
All Models: 8 twisted-pair ports meeting IEEE 802.3 10BaseT & IEEE 802.3u 100BaseTX standard specifications; Category 5 or better cable, 100 meters maximum distance for 100BaseTX, Category 3 or better cable, 100 meters maximum distance for 10BaseT. Auto MDI/MDI-X and Auto-Negotiation Function supported. Ports 1- 4 support IEEE 802.3af Power over Ethernet (PoE) as Power Source Equipment (PSE).
Models 065-7408P1FXSCTB and 065-7408P1FXSTTB: 1 100BaseFX port, 2 km Span, with SC Multimode (model 065-74091FXSCTB) or ST Multimode (model 065-74091FXSTTB) connectors.
Model 065-7408P1FXSMTB: 1 100BaseFX port, 20 km Span, with SC Singlemode connectors. Extended distance model spanning 40 km available by special order.
Global: Power1 (Green), Power2 (Green), Power3 (Green)
10/100BaseT/TX Ports and 100BaseFX Port: Link/Activity (Green)
Store and Forward
Buffer Memory: 1 Mbits
1,024 MAC Addresses
Forwarding Rate: 14,880 pps for 10 Mbps, 148,800 pps for 100 Mbps
Latency: less than 7.1 μs
Safety: UL1604: Classified for ITE Equipment for use in hazardous locations:
Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25C < Tamb < 74C
UL 60950, EN 60950-1, IEC 60950-1; IEC 61000-6-2
EMI: FCC Part 15 Class A; EN61000-6-2; EN61000-6-3
EMS:
ESD Standards (IEC 61000-4-2):
Enclosure Contact: + / - 4KV; Criteria B;
Enclosure Air: + / - 8KV; Criteria B
Radiated FRI Standards (IEC 61000-4-3):
Enclosure Ports: 10V/m, 80 to 1000 MHz, 80% AM; Criteria A |
Burst Standards (IEC 61000-4-4):
Enclosure Ports: + / - 4KV @ 2.5 KHz; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
A.C. Power Ports: + / - 4KV; Criteria B
Surge Standards (IEC 61000-4-5):
Signal Ports: + / - 1KV; Line-to-line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B
A.C. Power Ports: + / - 2KV; Line-to-earth; Criteria B
Induced RFI Standards (IEC 61000-4-6):
Signal Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
D.C. Power Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
A.C. Power Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
Earth Ground Ports: 10V RMS @ 0.15 - 80 MHz, 80% AM; Criteria A
Magnetic Field Standards (IEC 61000-4-8):
30A/m @ 50, 60 Hz; Criteria A
Voltage Dip Standards (IEC 61000-4-11):
A.C. Power Ports: 30% Reduction for 0.5 period; Criteria B
Environmental Test Compliance:
Vibration Resistance (IEC 60068-2-6fc):
5G @ 150 Hz (Operation/Storage/Transport); Criterion 3
Shock (IEC 60068-2-27):
25G @ 11ms (Half-Sine Shock Pulse; Operation);
50G @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
Free Fall (IEC 60068-2-32 Ed): 1 Meter (3.281 ft.)
NEMA TS1/2 Environmental Requirements for Traffic Control Equipment
Dimensions: 2.68 in.W x 5.35 in. Hx 4.33 in.D (68 mm x 136 mm x 110 mm)
Housing: IP20 protection, metal case
Weight: 2.2 lb (1 kg.)
Included DIN-rail mount. Optional wall mounting bracket available by special order.
- ELECTRICAL CHARACTERISTICS:
Maximum Power Consumption: 72 Watts
Maximum Current Drawn: 48 V DC @ 1.5 A
DC Input: 48 V DC, connected via redundant terminal block rated at 2.5 A.
Optional hardened 48 V DC power supply sold separately.
- ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: -40°F to 167°F (-40°C to 75°C); tested to -40°F to 185°F (-40°C to 85°C)
Storage Temperature: -50°F to 200°F (-45°C to 93°C)
Operating Humidity: 5 to 95% (non-condensing)
5 years |