SPECIFICATIONS:
* APPLICABLE STANDARDS
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX / 100BaseFX
IEEE 802.3x Flow Control and Back pressure
* FIXED PORTS
All Models: 5 (model 065-7405TB) or 8 (models 065-7408ATB, 065-74091FXSCTB, and 065-74091FXSTTB) twisted-pair ports meeting IEEE 802.3 10BaseT & IEEE 802.3u 100BaseTX standard specifications; Category 5 or better cable, 100 meters maximum distance for 100BaseTX, Category 3 or better cable, 100 meters maximum distance for 10BaseT. Auto MDI/MDI-X and Auto-Negotiation Function supported.
Models 065-74091FXSCTB and 065-74091FXSTTB: 1 100BaseFX port, 2 km Span, with SC Multimode (model 065-74091FXSC) or ST Multimode (model 065-74091FXST) connectors.
* LED STATUS INDICATORS
Global: Power1 (Green), Power2 (Green), Fault (Red)
10/100BaseT/TX Ports: Link/Activity (Green), 100 Mbps Speed (Amber)
100BaseFX Port (Models 065-74091FXSCTB and 065-74091FXSTTB): Link/Activity (Green), 100 Mbps Speed (Amber)
* SWITCH ARCHITECTURE
Store and Forward
Buffer Memory:768 kbits
2,048 MAC Addresses
* PERFORMANCE
Forwarding Rate: 14,880 pps for 10 Mbps, 148,800 pps for 100 Mbps
Latency: less than 7.1 μs
* CERTIFICATIONS
Safety: UL1604: Classified for ITE Equipment for use in hazardous locations:
Class 1, Division 2 group A, B, C, & D: Temp Code T4A; -25C < Tamb < 74C
EN 60950-1, IEC 60950-1; IEC 61000-6-2
EMI: FCC Part 15 Class A; EN61000-6-2; EN61000-6-3
EMS:
ESD Standards (IEC 61000-4-2):
Enclosure Contact: + / - 4KV; Criteria B;
Enclosure Air: + / - 8KV; Criteria B
Radiated FRI Standards (IEC 61000-4-3):
Enclosure Ports: 10V/m, 80 to 1000 MHz, 80% AM; Criteria A
Burst Standards (IEC 61000-4-4):
Enclosure Ports: + / - 4KV @ 2.5 KHz; Criteria B
D.C. Power Ports: + / - 4KV; Criteria B
A.C. Power Ports: + / - 4KV; Criteria B
Surge Standards (IEC 61000-4-5):
Signal Ports: + / - 1KV; Line-to-line; Criteria B
D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B
A.C. Power Ports: + / - 2KV; Line-to-earth; Criteria B
Induced RFI Standards (IEC 61000-4-6):
Signal Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
D.C. Power Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
A.C. Power Ports: 10V RMS @ 0.15-80 MHz, 80% AM; Criteria A
Earth Ground Ports: 10V RMS @ 0.15 - 80 MHz, 80% AM; Criteria A
Magnetic Field Standards (IEC 61000-4-8):
30A/m @ 50, 60 Hz; Criteria A
Voltage Dip Standards (IEC 61000-4-11):
A.C. Power Ports: 30% Reduction for 0.5 period; Criteria B
Environmental Test Compliance:
Vibration Resistance (IEC 60068-2-6fc):
5G @ 150 Hz (Operation/Storage/Transport); Criterion 3
Shock (IEC 60068-2-27):
25G @ 11ms (Half-Sine Shock Pulse; Operation);
50G @ 11ms (Half-Sine Shock Pulse; Storage/Transport)
Free Fall (IEC 60068-2-32 Ed): 1 Meter (3.281 ft.)
NEMA TS1/2 Environmental Requirements for Traffic Control Equipment
* PHYSICAL CHARACTERISTICS
Dimensions: 1.97 in.W x 5.35 in. Hx 4.33 in.D (50 mm x 136 mm x 110 mm)
Housing: IP30 protection, metal case
Weight: 1.76 lb (0.8 kg.)
* INSTALLATION
Included DIN-rail mount. Optional wall mounting bracket available by special order.
* ELECTRICAL CHARACTERISTICS
Maximum Power Consumption: 18.72 Watts
Maximum Current Drawn: 12 V DC @ 0.99 A, 24 V DC @ 0.55 A, 48 V DC @ 0.39 A
DC Input Range: 12 to 48 V DC, connected via redundant terminal block. Optional hardened power supply sold separately.
* ENVIRONMENTAL CHARACTERISTICS
Operating Temperature: -40°F to 167°F (-40°C to 75°C)
Storage Temperature: -50°F to 200°F (-45°C to 93°C)
Operating Humidity: 10 to 95% (non-condensing)
* WARRANTY
5 years