Great Lakes Data Cabinets

Data Cabinets

Racks and Cable Channel

Wall Mount Racks and Brackets

Wall Mount Racks
Vertical Hinged Wall Mount Brackets
Swing Gate Racks
Hinged Wall Mount Brackets

Rack Accessories

Trays and Shelves

Cable Management

Ladder Rack
Vertical Rings
Rack Mount Rear Cable Management Bar
Metal Ring Panels
Metal Interbay Panels
Extended Cable Management Bracket
Clip Panels
Cable Management Ring Panels
Cable Management Panel Covers
Cable Management Interbay Panels
Cable Management Finger Duct Panels
Blank Panels

 
About Us
cable, vdsl, patch

 

Great Lakes 10kw Cooling Racks-10Kw Cooling Racks, 10kW Cooling Data Cabinets-- Great Lakes Data Cabinets-Great Lakes 4kw Cooling Racks,4Kw Cooling Racks- Cooling Data Cabinets

Welcome to Data Center Power and Data Cabinet Cooling for the Future

Call us at (866) 342-3721 For Configuration- Engineering or Pricing

Great Lakes Lake Effect Cabinets- Up to 10kW Cooling Efficiency

American Tech Supply is a Tier One direct distributor of Great Lakes Case and Cabinets and offers the complete line of Great Lakes Data Cabinets, Great Lakes Water Cooled Data Cabinets,Closed Loop Water Cooled Enclosures and their entire line of 2 post racks, 4 post racks and data center racking systems. Most Great Lakes standard data cabinets and racks ship same or next day after receipt of order. The Great Lakes Chilled Water Cooled Systems are not same day or next day as they have to be custom -built based on your engineering requirements. Please choose the chilled or cooling system you need below. Our representatives will work with you on putting together complimentary engineering services to customize your data center cooling needs. Please call us at (866) 342-3721 or email us for further information.

ATS is now a Tier 1 Distributor of Great Lakes Cabinets! Great Lakes SPECIALIZES IN same OR next DAY SHIPPING ON ALL DATA CABINETS AND RACKS!- More details

10 kW Cooling options make the most of the core elements included in each Great Lakes ES Series Enclosure

A Medium (10kW) cooling solution can also be easily implemented

Thermal patented technology makes the Great Lakes Lake Effect Enclosure your solution for all your networking needs. This Enclosure eliminates the use of refrigerants or coolants in your data center environment. The use of vanaxial fans originally designed for the aerospace industry allows this enclosure to create a usable air environment which can satisfy up to a 10KW of computer load. A consistent 65 degree temperature in the front plenum chamber is maintained from top to bottom, there by protecting your equipment from hardware failure due to overheating.  It contains a 44 RMU rack space, and all the same features as our Great Lakes Enhanced Series Enclosures.

In a typical raised floor data center, conditioned air moving vertically from a raised floor or empty data center space (white space) is being asked to pass into an enclosure, in order to cool the equipment mounted inside. The result is a lot of “white space” being cooled. The Adjustable Air Manager mounts in the bottom of a Great Lakes ES Series Enclosure on a raised floor to bring the conditioned air inside the enclosure closer to (and helping it pass though) the equipment to be cooled. A simple slide on the Air Manager allows you to control the flow of conditioned air coming into the bottom of the cabinet. This increases air flow to and lowers intake temperatures in the front of the equipment, while also maintaining air pressure within the enclosure. The Air Manager also uses the Great Lakes concept ofAccelerated Ambient Cooling to greatly improve the efficiency of the available conditioned air intended to cool equipment mounted within the enclosure. By managing and directing the available conditioned air, it nearly eliminates bypass air flow outside the enclosure.
This effect can be further enhanced through the use of an optional high-efficiency fan unit, mounted within the Air Manager to increase the acceleration of air into the enclosure. Other compatible accessories include Great Lakes’ Brush Grommet Kit to keep any conditioned air from bypassing the equipment mounted within the enclosure. An optional Exhaust Chimney can further increase CRAC unit efficiency by directing hot air to the system return, completing the “loop”. In essence, this “localizes containment” at the enclosure level. The use of these optional accessories helps the enclosure to do everything it can to maximize the existing conditions within a given data center, without adding any additional, outside cooling.
This High Cooling Solution would be targeted at the delivery of 10 kW, based on the various options, accessories and techniques employed, as well as the conditions and efficiency of the computer room air conditioning system employed in.

 

 

What's special about these thermal enclosures?

  • Lake Effect base unit with two (2) pair of power coated 19” universal M6 rails and M6 hardware, shipping pallet, and two (2) sets of power strip brackets
  • Plexiglas front door and mesh rear door
  • Optional Retro Kit can bolt into any standard 19" EIA rack – uses bottom 7 RMU only
  • Cabinet to Cabinet wiring capabilities
  • No infrastructure changes to install
  • No water or refrigerants or any other liquid introduced into data center environment
  • No additional piping, duct work or floor modifications necessary
  • Will not invade under floor of cabinet
  • Does not infringe on existing  raised floor pressure
  • Vanaxial fans
  • Directional airflow of up to 1224 CFM to the intake of the servers
  • Environmental monitoring available
  • Wide range of PDU’s available
  • Intake Ambient Air: 65° F

Enhancing Features :

  • Local and remote monitoring
  • Remote re-boot control
  • Single or Dual Power Feed
  • Digital Display
  • User-Friendly Software
  • Made in the U S A

 


In order to increase the cooling effect within the enclosure, the goal remains to direct conditioned air and to restrict the possibility of hot air recirculation. At the same time, any proposed solution must also allow for any desired cable management in the front of an enclosure.

The Lake Effect Thermal Enclosure utilizes the proprietary concept of “accelerated ambient cooling” to provide an even flow of available low temperature air to the front intake face of servers and equipment mounted inside the cabinet. That air is accelerated and directed by an 8 RMU fan box, within a pressurized plenum chamber, to more efficiently cool the mounted equipment, while minimizing any chance of by-pass airflow. This approach creates an environment which allows for the delivery of air at the same temperature and quality to the face of every server in the cabinet.

The Lake Effect server enclosure utilizes high performance vanaxial fans and the entire fan box draws less than 2 amps, allowing the Lake Effect enclosure to create a functional usable air environment with minimal power requirements.

(The number of servers which may be placed in an enclosed cabinet is directly related to the amount of air available to cool the equipment. The temperature available at the base of the fan box is limited to the ambient temperature associated with computer room air conditioning (CRAC) or base room temperature.)

The Lake Effect enclosure offers an environmentally responsible approach: requiring no infrastructure changes to implement. It can be deployed across a data center or employed selectively for high-density cabinets. The Lake Effect can be placed, configured and become operational immediately, maximizing available ambient air, conditioned or not.

3D Computational Thermal Analysis was independently tested and verified by Flomerics, using Flotherm software. Computer models were coupled with powerful fluid dynamic software that predicts airflow and heat transfer in and around electronic equipment. Model includes thirty-six 1 RMU servers dissipating 10,000 watts total, 10 kW+ (continuous load) equipment load, and even temperature across equipment intakes. (Intake ambient air 65°F, 1224 CFM at 1/8" H20 static pressure.)

Passive
The use of the Great Lakes Brush Grommet Kit, designed to mount to the proprietary Flexible Mounting Profile* found in each Great Lakes rail, helps to prevent bypass air flow and to keep conditioned air in the front of the enclosure. While brush grommet prevents hot air recirculation and prevents conditioned air from passing by the equipment mounted within the enclosure, it still allows for any desired cable management within the enclosure.

Active
A Medium Cooling solution could also include optional fans in the front mesh door in order to accelerate the intake of conditioned air into the front of the cabinet, as well as its movement through the equipment mounted within. The employment of split fan rear doors can assist in the removal of hot air from the enclosure. This solution can be further enhanced by the installation of an optional fixed/adjustable ducted chimney to channel the natural upward movement of hot air, removing it from the enclosure through an upper rear opening to which the chimney may be attached. Heat removal may be further activated by the addition of an exhaust fan, to be mounted within the chimney.

This Medium Cooling Solution is targeted at the delivery of 8 kW through the use of some simple enclosure options and accessories. Actual cooling shall be based on the options, accessories and techniques employed, as well as the conditions and efficiency of the computer room air conditioning system employed in the data center.

*The Flexible Mounting Profile (FMP) is a series of holes along each rail, installed at one-RMU increments, and located outside the standard pattern for all EIA rail-mounted equipment. From copper bus bars to cable rings, cable managment posts and other accessories, the design and manufacture of Great Lakes rails is so strong that virtually nothing mounted to the FMP will take away from the dimensional stability of the rail itself.

The rails in Great Lakes’ ES series enclosure are #12 gauge steel, formed three times for
added strength. An ES enclosure can support more than 2,000 pounds of mounted equipment.

Great Lakes PT#
Great Lakes Lake Effect Product Description
Dims Price EA
Custom Enclosure
GL-8401LE-3048 Lake Effect Base Unit with two (2) pair of powder coated 19” universal M6 rails and M6 hardware, shipping pallet, and two (2) sets of power strip brackets 84"H x 30"W x 48"D $1,914.87
GL-8402-LE Plexi door with lower bottom mesh- front for 84"H x 29"W Base Unit $573.48
GL-8402E-M29 Mesh steel door with locking swing handle - rear for 84"H x 29"W Base Unit $317.02
GL-8410-36ELS

Pair Locking Lift-off Solid Side Panels

84"H x 36"D $264.71
GL-TPE-29P Perforated Top Panel w/Two 4" Horseshoe Knock-outs - $63.41
GL-LE-CM Vertical cable management tray (2) - $180.38
GL-LE-FB Fan Box Kit, Patented
Great lakes patented technology achieves a positive air pressure environment, created by a 7 RMU fan box, 3 sided adjustable depth plenum both sealed to the front door. The servers/filler panels form the rear surface which yields a consistent temperature curtain at the front of the cabinet providing an environment that is the right temperature, the right air quality, delivering to the face of every computer in the cabinet.
- $4,528.44
GL-LE-PL Plenum kit, Patented - $789.48
Enclosure Kits (includes all the items above)
GL-GL840LE-3048 Lake Effect enclosure kit complete floor mount 84"H x 30"W x 48"D $8,085.54
GL-GL840LE-3048-LG Lake Effect enclosure kit complete with leveling glides 84"H x 30"W x 48"D $7,982.00
GL-GL840LE-3048-LGC Lake Effect enclosure kit complete with casters and levelers 84"H x 30"W x 48"D $8,068.00
Cabinet without Fan Box Kit and Plenum Kit
GL-GL840LE-3048-MC Lake Effect enclosure mesh contour front and rear doors without Fan Box and Plenum Kit 84"H x 30"W x 48"D $4,210.42
GL-GL840LE-3048-MC-LG Lake Effect enclosure with mesh contour front and rear doors without Fan Box and Plenum Kit (includes leveling glides) 84"H x 30"W x 48"D $4,276.82
GL-GL840LE-MC-LGC Lake Effect enclosure with mesh contour front and rear doors without Fan Box and Plenum Kit (includes leveling glides and casters) 84"H x 30"W x 48"D $4,377.11
 
GE-LIFT ***  If your delivery will require a LIFT GATE you must select this option. ***
American Tech Supply,IInc reserves the right to bill for those actual charges incurred from the shipping companies for services not identified by the customer.  These 'additional services/charges' include the following:  A lift gate, inside delivery & storage.
$125.00

PART #
Click below to view item
DESCRIPTION SIZE PRICE
Accessories
DOORS
GL-8404E-M29 Bevel mesh door (accepts 7217LE3 door fans) for 84"H x 29"W Base Unit $470.88
GL-8404E-MC24 Mesh Contour Steel Door - $370.78
GL-8402E-29SM Split mesh door for 84"H x 29"W Base Unit $420.04
GL-8404E-29 Plexiglas door with locking swing handle for 84"H x 29"W Base Unit $206.07
SIDE PANELS
GL-8411-36ELL Pair locking lift-off louvered side panels for 84"H x 36"D Base Unit $309.09
REMOVABLE TOP & BOTTOM PANELS
GL-TPES-S Solid Top Panel for ES & LE Racks for 29"W Base Unit $53.89
GL-TPES-P Perforated Top Panel for ES & LE Racks for 29"W Base Unit $55.48
GL-TPES-F Top Panel with Fan Assembly for ES & LE Racks for 29"W Base Unit $261.53
GL-TPES-F10 550 CFM 10" Fan Top Panel for ES & LE Racks for 29"W Base Unit $277.40
GL-TPES-2F10 2 x 550 CFM 10" Fan Top Panel for ES & LE Racks for 29"W Base Unit $473.94
CABLE MANAGEMENT
GL-LE-CM Vertical cable management tray (rear) - $180.38
GL-HCM-W29ES Waterfall cable management - $19.39
GL-VLB-8436 Vertical lacing bar kit (includes 1 vertical lacing bar, 2 horizontal lacing bars and 6 CM-01 cinch straps) for 84”H x 36”D enclosures $96.68
FILLER/BLANKING PANELS
GL-875-FP19 8.75”H, 19” Rack Mounting 5 RMU $19.82
GL-1400-FP19 9 14.00”H, 19” Rack Mounting 8 RMU $24.78
POWER OUTLET STRIPS, COPPER BUS BARS & COOLING EQUIPMENT
GL-7215
49" 16 Position Power Strip w/ Circuit Breaker, 5-15P plug, 5-15R Receptacle (16 outlets) 49" Length $101.45
GL-7215-S
6 position power strip with circuit breaker (19" rack mounted) 49" Length $150.58
GL-7215-20AR
49" 16 Position Power Strip w/ Circuit Breaker, 5-20P plug, 5-20R Receptacle (16 outlets) 49" Length $166.43
GL-7215-30A
16 position power strip w/circuit breaker & 5-20P plug 48" Length $315.43
DOOR HANDLES
GL-CH-01 Four digit combination handle - $52.88
GL-CH-02 Three digit combination handle - $77.11
GL-CH-03 Pad lock handle with key - $83.72
GL-CH-04 Pad lock handle - $77.11
COOLING DEVICES
GL-7217FT Fan tray with three 75 CFM fans  - $233.17
GL-7217FT-3 Front & rear mount, adjustable fan tray w/ three 75 CFM fans - $324.94
GL-7217FT-6 Front & rear mount, adjustable fan tray w/ six 75 CFM fans - $388.35
GL-7217FT-9 Front & rear mount, adjustable fan tray w/ nine 75 CFM fans - $515.16
GL-7217-LE1 Fan Assembly w/ fan adaptation plate (installs in rear top) - $258.12
GL-FTBKT90 Fan Bracket to mount the 7217-FT fan at a 90 degree angle - $31.70
GL-FTC101 Fan Thermostat Controller
Thermostat controlled 15 amp duplex outlets, UL listed, CSA certified thermostat,
50° to 90°F / 10° to 30°C temperature range, 6 ft. cord
- $188.62
GL-7217LE3 Fan kit w/three 75 CFM fans (door fan for use with 8404E-M29) - $233.33
MISC. ACCESSESSORIES
GL-LE-DP Divider panels (separates power from data) - $83.16
GL-LE-BKT Top Bonnet (accepts remote display) - $155.52
GL-HDW-105-25 Package of 25 M6 Cage Nuts with Screws 1.7 to 2.7mm Cage Nut / 12mm Screw - $25.34
GL-HDW-105-50 Package of 50 M6 Nuts with Screws 1.7 to 2.7mm Cage Nut / 12mm Screw - $40.03

Faster processors turn up the heat

With the way technology constantly advances, processors are running with greater speed and more capability than ever, but all of these advantages also bring one negative aspect: heat. Lots and lots of it. While the rest of us are reaping the benefits of faster networks, IT personnel are faced with the challenge of keeping server enclosures cool when all that equipment keeps cranking out the BTUs.
Many high-heat thermal management systems on the market are complex and invasive… they work well, but often involve pipes, cooling liquids and floor penetrations. But effective cooling doesn’t have to be so complicated. CableOrganizer.com offers an exceptional – and greatly simplified – cooling solution for high-density server rooms and data centers: the Lake Effect enclosure from Great Lakes.

Consistent cooling without the hassle

You’re probably wondering how a thermal management system that is free from pipes and liquid coolants can possibly be effective! The secret is in the Lake Effect enclosure’s patented technology, which uses vanaxial fans to deliver cool airflow – at a rate of 1224 CFM – to the front faces of servers. From there, the servers’ intake fans are then able to draw that cool air supply into the computers themselves. Lake Effect enclosures provide usable air environments for computer loads of up to 10KW.
Because the Lake Effect cabinet doesn’t rely on water or refrigerants, you won’t run the risk of exposing sensitive computer equipment to liquids. In addition, instead of drawing air from plenum or riser spaces, the enclosure uses ambient server room air for cooling. These two characteristics combine to create another benefit: this Great Lakes server cabinet is completely non-invasive! The Lake Effect enclosure doesn’t require pipe installation, duct work, or any other changes in infrastructure: just set it down on the existing raised floor of your server room or data center.

State of the Art Enhanced Features

There’s even more to the Lake Effect enclosure than revolutionary cooling technology and worry-free installation! In addition to standard features like cabinet-to-cabinet gangability and a wide selection of power distribution units, Great Lakes offers the following optional enhancements:

  • Easy to use Software
  • The ability to reboot via remote control
  • The choice of Single or Dual power feed
  • Local and remote environmental monitoring
  • Digital display
American Tech Supply is a national data cabinet supplier for Great Lakes and as a Tier One Data Cabinet distributor we carry the entire line of Great Lakes Water Cooled Cabinets, Great Lakes Data Rack Enclosures,Network Racks,Relay Racks, Cable Management Racks, Equipment Racks, and Rack Systems. Great Lakes Cabinets and Rack Systems are recognized around the globe as strong reliable partners in the areas of telecommunications and data communications, server network and technology, medical technology and, of course, security, and traffic control technology. The Great Lakes line of racks and data cabinets quality has been setting traditionally recognized high standards for several decades. Our standardized and customer-specific solutions are reflections of our innovative engineering know-how, which characterizes and provides the impetus for progress in these markets. Perfect solutions incorporating mechanical, electronic and thermal components qualify us as one of the global market leaders for highly developed, modular rack and enclosure systems for indoor and outdoor applications. The global presence, the innovative and aesthetic design, a mature platform of standard products and the recognized high degree of integration competence, supplemented by outstanding time-to-market results. American Tech's products are compatible with the latest standards established by Dell, HP, IBM, Lanstar, Chatsworth. APW,Rittal,Hoffman and other server rack and data cabinet suppliers. With locations through the US, we serve all regions of the United States, Canada, Hawaii, AK and South America. Please call us for additional shipments at (866) 342-3721


WATER COOLED CABINETS

The water cooled data cabinet or water cooled rack in a data center or equipment closet is now being classified as the most efficient means of transferring heat away from expensive equipment that may cost tens of thousands to replace if damaged. American Tech Supply as a leading rack supplier now carries a complete line of water cooled data cabinets and water cooled racks and carries the revolutionary water cooled data rack from Knurr and Emerson Network power for the ultimate in cooling and thermal temperature management for data cabinets and data centers with high temeperature requirements. The advantages of the simple and safe water cooled data cabinet and water cooled rack previously outweigh the disadvantage of the low heat transfer potential of gaseous coolants. In the meantime, the heat load in high-performance servers has exceeded the options of cost-effective cooling with air. The CoolTherm® range of 'water-cooled server cabinets or water cooled data cabinets' can provide a great advance in data cabinet thermal management, reducing computer room costs, while improving operational performance and reducing facility operating costs. Typical, high quantity conventional server cabinet layouts can effectively dissipate around 3.6kW each.

 

Knürr CoolTherm® water cooled racks and water cooled data cabinets are completely sealed off from the room air. The dissipation of the total power loss is made via an air-to-water heat exchanger in the base area or door of the rack, which is connected to the cold water system in the building. Redundant high-performance fans drive a closed cold air circulation in the rack’s interior. The built-in servers are supplied from the front with air that is brought to the right temperature of about 20–25°C (68 °F to 77 °F). The warmed air is collected at the rear topside in the rack, pushed down by the heat exchanger and back to the front, to the server front panels. There are no requirements for room thermal management; the rack system is fully independent from the room air. Knürr AG with its global front position in thermal management research and development once again sets the high technology standard. The company consequently already provides a water-cooled server rack in series production today – the Miracel CoolTherm. This highly efficient system does not divert any heat loads to the surrounding environment. Instead, the entire energy is routed via the cold water system of the building infrastructure. The computer units in the server rack are supplied with cooled air from the heat exchanger. Trade standard servers can consequently be used and simultaneously combine the advantages of water cooling with low space requirements and high heat transport. With the optimised heat exchanger and air guidance systems, the CoolTherm attains up to 20,000 watts cooling power. Water cooled racks-more info FOR MORE INFO OR CONTACT US -PLEASE VISIT OUR CONTACTS PAGE

A single CoolTherm® 19" data cabinet or data rack will manage a 22kW heat load, enabling an 80% reduction in present, typical conventional cabinet numbers within large data centers. Resultant floor space savings of significantly reduce the take-up of large areas of expensive computer room floor, as server power levels skyrocket.
Cabinet installation costs can also be halved and enormous year-on-year operational savings made in associated reductions in CRAC install and running costs.

 

Hoffman data cabinets-data cabinets-Racks-Raceways

Great Lakes data cabinets-data cabinets-Racks-Raceway Systems

ESW data cabinets-More Info

Quest data cabinets- data cabinets- Racks

data cabinets-Racks-Raceway Systems

ATS is now a Tier 1 Distributor of Great Lakes Cabinets! Great Lakes SPECIALIZES IN same OR next DAY SHIPPING ON ALL DATA CABINETS AND RACKS!- More details

 

 

We Now are An APC Distributor- More Info Water Cooled Data Cabinets- More Info

American Tech Supply offers Newton Data Cabinets, Hoffman Data cabinets, Quest Data Cabinets, ESW Data Cabinets, Cooper Data Cabinets, B-Line Data Cabinets, Quest Data Cabinets, and cabinets from other manufacturers by request.

LAN Rack Accessories- Keyboard trays-Shelves KVM Switches

We carry cable management racks, Wallmount Rack and wallmount rack solutions for applications ranging from data centers, server rooms, to all office envrironments. Not only will ATS will meet or beat all US based pricing- but will assist you in designing your network at NO EXTRA CHARGE. Call us for details at (866) 342-3721.

Wall Mount Racks and LAN Stations from ICC,Signamax, Hoffman,Ortronics,Kendall Howard and more.

 

l Infrastructure in medium data centers containing 20 - 100 racks.

 

(Rooms of 100+ Racks, Utilizing 200kW Modules)
On-demand architecture for Network-critical Physical Infrastructure in large data centers containing 100+ racks

 

 

 

 

 

 

 

 

 

 

Rack Mount Shelves

Raceway

Cable Management

MPO Cassettes

MTP Fiber Cassettes

Fiber Optic Assemblies-Fiber Optic Jumpers

Fiber Optic Enclosures