Data- Telecom Equipment
     About Us

Firestop- Firestop Products- Firestop Supplier- Firestop Distributor- FireStop Protection

American Tech Supply is a national Nelson Firestop Supplier and Nelson Firestop Distributor,and carries a complete line of Firestop Products and Fire Stop Protection products. Our complete line of firestop fire protection products helps stop the spread of fire, smoke and toxic fumes. Our firestop fire protection produsts are easy to install and are approved for a wide variety of firestop applications by Underwriter’s Laboratories. Total passive firestop and 'fire' protection cannot be achieved with the use of a singular product. It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

ATS stocks firestop products from the leading firestop manufacturers in the USA.

Firestopping has been the sole focus at Nelson for nearly four decades. Nelso Firestop Products offer the right class of protection for virtually any penetration, in any building, anywhere in the world. If you want to specify the best firestop solution for any given application, in the U.S. or overseas, Nelson is the company for a quick accurate response. With products you can depend on. From people you can depend on. Nelson makes it easy.

Commercial Products

 CLK  CMP CPS
 ES1399  FIRE BRICK FSC
 FSC3  FSP LBS3
 MCT/MPS  PCS PLW
 WRS3  LIGHT COVER  

 

 
Nelson Firestop - CLK™ Silicone Sealant

 

     
 
Nelson Firestop - CMP™ Compound

 

     
 
Nelson Firestop - CPS™ Composite Sheet
     
 
Nelson Firestop - ES1399™ Elastomeric Sealant

 

     
 
Nelson FIRE BRICK

 

     
 
Nelson Firestop - FSC™ Cable Coating

 

     
 
Nelson Firestop - FSC3™ Joint Coating

 

     
 
Nelson Firestop - FSP™ Putty Bar and Pad


     
 
Nelson Firestop - LBS3™ Latex Sealant

 

     
 
Nelson MCT™, MPS™, and EMCT™

 

     
 
Nelson Firestop - PCS™ Pipe Choke System

 

     
 
Nelson Firstop - PLW™ Pillow

 

     
 
Nelson Firestop - WRS3™ Wrap Strip


     
 
Firestop Lighting Covers


 

List of Tests Successfully Performed On MCT
     
  (All tests were performed using steel frames. Aluminum were frames used for other environmental conditions, such as a moisture barrier.)

- Capacitance comparison test on various types of coaxial cables
- Watertight integrity test on Multi-Cable transit utilizing Nelson "Cast Enclosure" (200PISG)
- Cable temperature rise in MCT™ (derating not required)
- Preliminary cable holding tests on MCT™ for THW, 600V and 5000V cable. Meets or exceeds NEC
- Class I Group D, explosion test
- Helium leak test of Multi-Cable Transit
- Four hour fire test witnessed by an independent utility representative
- Three hour fire and hose test
- MCT™ eddy current test
- Class I, Group B explosion test for hazardous environment
- Fire test with aluminum conduit
- Sound attenuation analysis of MCT™, 125-4000 HZ
- Two hour PVC pipe test
- Four hour fire test on a bus duct
- QPL 24705 2000°F fire test on fiber optic bundles

- Lockheed Electronics 1578C-4454 one hour fire test (U.S. Navy and U.S. Coast Guard) for bulkheads. ASTM-E119 and Solas (Safety of Life at Sea) are basic testing documents.
- Metallurgical Processing Laboratory - one hour fire test for ships deck. Same activities and regulations as above.
- Lockheed Electronics 1578B-4454 MIL-S-901C shock test.
- Lockheed Electronics 1578-4454 MIL-STD-167 vibration test.
- Westinghouse Canada CWAPD-15 2 x 108 effects of gamma radiation on MCT components.
- Underwriters Laboratory R7269-2 two hour fire test "Wall Opening Protective Multiple Cable Device For use in Masonry Walls". This was a fire and hose stream test.
- National Research Council of Canada two hour fire test on cable and conduit with Positive Pressure.
- HCL (Hydrogen Chloride) emission test on modules by Bridgeport Testing Laboratory. Compares our emission to that of various cable jackets. (HCL emission from Tecron™ is infinitesimal)
- Underwriters Laboratory three hour fire and hose stream test on block and brick masonry walls.
- Underwriters Laboratory three hour fire test on concrete floor slab.
- Class 1 Group A, B, C & D explosion test for hazardous environment.
- Attenuation Comparison under Compression for fiber optic cables.
- IMO A.754 (18) H-120 hydrocarbon fire test by Southwest Research Institute
- IMO A.754 (18) A, B & F O-60 Fire Rated Deck & Bulkhead

- Multi-Cable Transit and Multi-Plugs are now qualified under MIL-P-24705/1 and MIL-P-24705/3: Approval Letter Naval Sea Systems Command 4123 OPR: 05Q2/312 Dated April 30, 1993.
- Hi-Test Laboratories 525 MIL-P-24705A Type 1 Environmental Vibration Test (MIL-STD-167-1)
- Hi-Test Laboratories 526 MIL-P-24705A High Impact Shock Test (MIL-S-901D)
- QPL 2000°F Fire Test T200.217; witnessed by DCMDS Inspection Office Representative
- Hi-Shock Platform Test/Technical Report 15-71 (2700PSI Maximum Instantaneous Pressure Impact)

 

     

What is firestop?

Firestop and Firestopping is an integral part of fire protection engineering.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Firerated Innerduct-Click Here

Firestop and Firestopping is an integral part of fire protection engineering in all commercial buildings and are required by law in most states to satisfy mandated laws for commercial building fire protection.  Firestop systems protect against the passage of flames, deadly gases and toxic smoke through openings that are created for penetrations, joints and gaps in fire-resistive walls, floors and floor/ceiling assemblies.  The integrity of fire-rated assemblies is restored by firestop systems.  Building codes require third-party tested systems to be installed whenever fire-rated construction is compromised by such openings. 

Telecomm cables found in a Hospital, the day before a Joint Commission Inspection. Cables were sleeved without having to be removed with our Split Sleeve & Bulkhead System.

What is meant by "active" and "passive" fire protection?

Active fire suppression includes mechanical systems such as sprinklers,  that are designed to extinguish fires after they have started.  Passive fire protection functions to contain fires within the areas in which they start, preventing loss of life by preventing the products of combustion (smoke, hot gasses and flames) from spreading throughout a building.

Why is "passive" fire protection necessary?

Fire is a dangerous enough phenomenon that redundancy in fire protection is necessary.  Having passive protection in place helps assure building occupants that there will be time to exit before gasses, fire and smoke spread throughout the building.  If  active systems fail, as they often do, then there is still a passive system in place for life safety.

It is the use of many products designed for specific firestop applications that comprise a complete passive firestop fire protection systems. When installed properly, these firestop products work in concert with one another to create effective barriers against the passage of flames, smoke, and superheated gases. Used is conjunction with other firestop fire protection methods, properly installed passive fire protection will save lives, protect property, and minimize business losses.

Joints

Construction joints must be sealed with joint systems, which will impart a fire resistance at least equal to those of the adjacent constructions so that overall fire resistance is not compromised.

Additional Information -Applications Click Here

Fire resistive joint systems are used in building construction to seal joints, and must be of the same or greater fire resistance (temperature) rating as the wall or floor containing the opening which they are designed to protect. Perimeter joint systems are most often used to seal a clearance separation between curtain walls and floors. They are designed to accommodate various movements induced

In fact, we’re one of the leading suppliers that can provide fully tested systems to firestop all of these scenarios:

From the leader in fire protection...
Our manufacturer partners have been creating innovative firestop systems for more than 25 years. Our complete line of fire protection products helps stop the spread of fire, smoke and toxic fumes. They’re easy to install and are approved for a wide variety of firestop applications including but not all: Underwriter’s Laboratories, Factory Mutual and Omega Point Laboratories. American Data Supply as a distributor can provide fully tested systems to firestop all of these scenarios:

  • Structural steel
  • Emergency circuitry
  • Grease/air ducts
  • Through penetrations
  • Perimeter joints
  • Fire resistive joints

Please Visit Our Product Links Below:

CT 120 Cable Transits- Designed for single or multiple cables-easy to install and alter cabling-use in floats & walks-including drywall

Firestop Products Data Sheets

Call (866) 342-3721 Or Click On The Chat Button At The Top Of The Page To Talk To One Of Our Representatives

Abesco CT120 Cable Transits are designed to prevent the spread of fire from one compartment to another where electrical, data, and communication cables penetrate through separating walls and floors.

Abesco CT120 Cable Transits consist of a square section steel sleeve, which contains the heat reactive intumescent material. The unit has an integral hinged top which provides an easy retro-fit option where cables are pre-installed. Abesco CT Mounting Plates provide a quick and easy method of installing single or multiple CT120 Cable Transits. even in drywall partitions.

WHY USE ABESCO CT120 CABLE TRANSITS ?

  • Manufactured to ISO 9001:2000
  • Corrosion resistant suitable for use in aggressive environments
  • Certification for a wide range of cables Available in a range of sizes
  • Very easy to install and provides total flexibility in cable routing
  • Abesco graphite intumescent is unaffected by moisture
  • Approved worldwide and recognized by independent authorities and tested in accordance with
    • ASTM E-814 (UL 1479)
    • BS 476
    • AS 1530.4
    • BS EN 1366-3

WHERE DO I USE ABESCO CT120 CABLE TRANSITS ?

 Abesco CT120 Cable Transits are suitable for use in any building where electrical, data, or communication cables penetrate through fire rated compartment floors and walls, including drywall.

Typical types of buildings where Abesco CT120 Cable Transits are commonly used are :

Banking and finance buildings, data processing centers, TV and media studios, apartment buildings, hotels, office buildings, hospitals, airports, retail centers etc.

WHAT HAPPENS IN A FIRE SITUATION ?

When exposed to the heat of a fire, the graphite based intumescent material contained in the Abesco CT120 Cable Transits expands rapidly to close and seal the inside of the sleeve, preventing the spread of fire from one compartment to another.

Additional Firestop Links Below:

Alliance for Fire and Smoke Containment and Control (AFSCC)

The American Institute of Architects (AIA)

American National Standards Institute (ANSI)

American Society for Testing and Materials (ASTM)

Building Officials and Code Administrators International (BOCA)

Canadian Fire Safety Association (CFSA)

Factory Mutual Research Corp (FMRC)

OTHER PRODUCTS

Abesco supply a wide range of Firestop products which provide the specifier, engineer and contractor with cost effective solutions to most passive fire protection problems experienced on todays construction projects.

We will beat any US-Based Company's Price On Firestop - CableTray or Raceway!

Raceway System Solutions- Cable Tray Systems-Cable tray-Cable trays-Cable Tray Systems-Raceway Systems- Flextray-Basket Tray

Snake Tray Cabletray-Raceway Systems Snake Loop

cisco systems
Telco Systems
Anritsu
Leviton
telecom supply
 
- 2010 All Rights Reserved -
 

 

 

C